FDA, LFGB and GB 4806: Food-Contact Compliance for Silicone Products

HOME >> BLOG

FDA, LFGB and GB 4806: Food-Contact Compliance for Silicone Products

Time:2026-11-07
Read:102

Food-contact compliance for silicone comes down to three questions: which regulation applies to the market you sell into, which tests that regulation actually requires, and whether the report in your inbox covers the product you are buying. "FDA approved" answers none of them. Here is how each regime works, what the tests measure, and how to verify a report in ten minutes.

The three regimes at a glance

Silicone food-contact articles are regulated as rubber, not as plastic, which is the first place buyers go wrong. A report quoting an EU plastics regulation does not cover a silicone spatula, however official it looks.

MarketFrameworkWhat is assessedDocument to request
United StatesFDA 21 CFR 177.2600Extractable fractions after reflux in distilled water and n-hexaneTest report from an accredited laboratory
Germany / EU retailLFGB section 30 and 31Sensory evaluation plus migration of constituentsLFGB test report
ChinaGB 4806.11 with GB 31604 methodsOverall migration, potassium permanganate consumption, heavy metalsCMA or CNAS report
EU frameworkRegulation (EC) 1935/2004Inertness; no transfer that endangers health or changes the foodDeclaration of Compliance with supporting data

What the tests actually measure

FDA 21 CFR 177.2600 is an extraction test. The article is refluxed in distilled water and in n-hexane, and the weight of material extracted is compared against limits. The water extraction is a proxy for aqueous foods; the hexane extraction is a proxy for fatty foods, and it is the one that fails most often, because it pulls out low-molecular-weight material that a poorly post-cured part still contains.

LFGB section 30 and 31 combines a sensory panel with migration testing. The sensory test — odour and taste transferred to a simulant — is subjective but decisive, and it is frequently the item that stops an approval even when the analytical numbers pass. GB 4806.11 works on overall migration plus potassium permanganate consumption, which is effectively a measure of oxidisable organic residue and therefore of cure quality.

Why a "food grade certificate" is usually not a certificate

  • It is a test report, not a certificate. It applies to the specific samples submitted, on the date they were tested. It does not certify a material family or a factory.
  • The scope does not match your part. A report issued for a 3 mm spatula head says little about a 1.2 mm teether, because thickness and surface-to-volume ratio change the extraction result.
  • It is issued to a trader. If the applicant is a trading company, the report tells you nothing about which factory moulded the sample or whether the same compound is used on your run.
  • No standard number, or the wrong one. A "food grade" page without 21 CFR 177.2600, LFGB 30/31 or GB 4806.11 is decoration. So is a report citing an EU plastics regulation for a silicone part.
  • Cover page only. The interesting content is the sample description, the simulant, the temperature and the result table — none of which appear on a cover page.

Matching the test to the product

  • Fatty contact (baking mats, spatulas, food storage lids) needs the fatty-food simulant or the hexane extraction, not just water.
  • Repeated use requires three successive migration tests on the same article, not one.
  • High temperature use — microwave, oven, dishwasher — must be reflected in the test temperature, otherwise the report covers a use condition you do not sell into.
  • Printed or coated surfaces need their own assessment; ink and coating are separate materials in contact with food.
  • Colour matters. Pigments are the usual source of migration failures, so test the darkest and most heavily loaded colour, or test each colour if the palette is wide.

Where silicone actually fails, and why

Almost every failure traces back to cure, not to the base polymer. Peroxide-cured silicone leaves decomposition by-products that show up as odour and as volatiles; a two-stage post-cure removes them, and skipping or shortening it is the cheapest corner a factory can cut. Heavy filler loading reduces cost and also reduces the extraction performance margin. Platinum cure is cleaner but is not automatically compliant — it still needs the right post-cure and a clean compound.

This is why the question to ask is not "is your silicone food grade" but "what post-cure cycle do you run, and can I see the report for this exact compound in this exact colour".

Verifying a report in ten minutes

  1. Check the accreditation mark. CNAS, CMA or an ILAC-MRA signatory lab. The certificate number should be traceable on the accreditation body's site.
  2. Read the sample description. Material type, colour, model number and a photo. If it does not describe your part, the report is not yours.
  3. Confirm the standard and year. An obsolete edition is a weak document, and some buyers will reject it outright.
  4. Compare test conditions with your use. Simulant, temperature and duration, and whether repeated use was tested.
  5. Check the date and the applicant. A report older than two or three years, or issued to an unrelated company, needs an explanation.
  6. Call the lab. A report number and a two-minute phone call settles authenticity faster than any amount of emailing.

FAQ

Do I need FDA approval to import silicone kitchenware into the US?

No. There is no pre-market approval for food-contact articles. The obligation sits with the supplier to use compliant materials and with the importer to exercise due diligence, which in practice means holding a test report and a material declaration. Retailers will usually ask for both.

Is an LFGB report valid across the whole EU?

LFGB is German law. The EU framework is Regulation (EC) 1935/2004, and national rules still differ. In practice most European retailers accept an LFGB report as evidence of suitability, but if you sell into France or Italy, check whether the buyer wants national requirements covered too.

Does one report cover every colour in my range?

No. Migration behaviour depends on the pigment and its loading. Either test the worst case and justify it in writing, or test each colour. Assuming coverage is how a compliant product fails a retail audit.

Is food grade the same as medical grade?

No. Medical grades require a different testing regime, tighter extractables control and often a controlled manufacturing environment. A food-contact report does not support a medical claim, and marketing one as the other is a regulatory risk.

Next step

If you need a food-contact programme that will survive a retail audit, send the part, the target market and the intended use condition. We will tell you which tests apply, which colour to submit as worst case, and what the post-cure needs to be. Start with silicone kitchen products for reference constructions, or see silicone baby products where the compliance bar is higher still.